Constant-Current Source Creates Slope-Compensation Ramp In SMPS

Focus:

In power supplies that employ peak current-mode control a ramp signal is required to slope-compensate the current control loop. A simple, constant-current-source ramp generator improves power supply stability and accuracy versus other methods of ramp generation.


What you’ll learn:

  • How to generate a ramp signal for compensation with slope that is independent of power supply input voltage


Notes:

ED's Ideas For Design


View the Source


Author & Publication:

Claude Abraham, staff engineer, Bendix Commercial Vehicle Systems, Elyria, Ohio, Electronic Design, Oct 11 2007