Interbundle Penetration Of Wire Bundles Improves Their Packing Factor Focus: When winding transformers or coupled inductors with twisted wiring bundles, turns of adjacent
wire bundles are typically wound close-packed to maximize packing factor (and in particular,
packing porosity) and ultimately maximize winding current density. Bundles of a small number of
strands can pack together more closely than those with a large number of strands because of the
sinusoidal variation in their outside diameter. This article examines the extent to which
twisted wire bundles can penetrate each other by fitting into the dips in adjacent windings and
thereby increase packing factor. This analysis quantifies the relationship between the number
of strands in a twisted wire bundle and the extent to which one wiring bundle penetrates or
“meshes with” the other.
What you’ll learn: - How to determine the degree of interbundle penetration achieved with wiring bundles used to wind
transformers
View the Source
Author & Publication: Dennis Feucht, Innovatia Laboratories, Cayo, Belize, How2Power Today, Nov 15 2018
|
This article summary appears
in the HOW2POWER Design Guide.
The Design Guide offers
organized access to
hundreds of articles
on dozens of power conversion
and power management topics.
The Design Guide search results
include exclusive summaries
and accurate "how to" analysis
to help you make faster,
more informed decisions.
Search
for more
articles
|