Calculating Minimum Magnetic Core Size For A Transformer Focus: In inductors the load current is the core magnetizing current, while in transformers the
core magnetizing current is separate from the load current. This is why in inductors
(chokes) the size-defining parameter is operating power, while in transformers the
magnetizing current ripple, which may constitute 0.5% to 1% of the input ac current,
determines core saturation and thus the minimum size of the core. This article provides an
analysis that clarifies and defines this relationship between magnetizing current ripple
and core volume, and in the process derives the equation needed to determine minimum core
size in a power converter application. It then demonstrates the application of this
equation with a transformer design example. Factors contributing to a smaller value of
magnetizing current (and therefore a smaller minimum core size) and the impact of winding
requirements on minimum core size are also noted.
What you’ll learn: - How to determine the minimum core size for a transformer used in a power converter
application
- How to understand why core volume is a function of magnetizing current in a power supply
transformer
View the Source
Author & Publication: Gregory Mirsky, Design Engineer, Deer Park, Ill., How2Power Today, May 13 2022
|
This article summary appears
in the HOW2POWER Design Guide.
The Design Guide offers
organized access to
hundreds of articles
on dozens of power conversion
and power management topics.
The Design Guide search results
include exclusive summaries
and accurate "how to" analysis
to help you make faster,
more informed decisions.
Search
for more
articles
|