Measuring Loop Response Of Regulators With Inaccessible Feedback Resistor Focus: For a power supply to be stable, certain gain and phase margins are needed. The
conventional approach of making Bode plot measurements is preferred for its simplicity,
assuming the user has access to the top feedback resistor. But how can the loop response
be measured when the top feedback resistor is inaccessible within a molded module? Or when
a device does not require a top feedback resistor and instead uses an output voltage sense
pin? This article presents two variations on the conventional loop response measurement
method, which use the same instrument but with some changes in the connection to the
regulator and (in one case) some simple additional circuitry. Example results for one of
the novel methods are checked against those obtained with the conventional method.
What you’ll learn: - How to make Bode measurements of voltage regulator stability when the top feedback resistor
is inaccessible
- How to make Bode measurements of voltage regulator stability when the regulator uses an
output voltage sense pin
View the Source
Author & Publication: Adam Huff, Xu Zhang and George (Zhijun) Qian, Analog Devices, San Jose, Calif., How2Power Today, Jun 13 2025
|
This article summary appears
in the HOW2POWER Design Guide.
The Design Guide offers
organized access to
hundreds of articles
on dozens of power conversion
and power management topics.
The Design Guide search results
include exclusive summaries
and accurate "how to" analysis
to help you make faster,
more informed decisions.
Search
for more
articles
|